Start with the assembly rating, not the bucket label
For a 600 A motor-control center, first document the marking that identifies the assembly or its bus rating, including where the marking appears and which section it refers to. A 600 A bus designation describes the marked assembly characteristic; it does not establish the rating of every feeder, starter, or protective device installed in it. If an inventory sheet says only “600 amp MCC,” preserve that wording as a preliminary description, then verify the nameplate and section identification from a safely accessible exterior position. Do not treat a visible 600 A device marking as proof that the entire center is rated 600 A. Keep assembly evidence distinct from individual bucket evidence.
Map sections and buckets as separate inventory units
Record each section separately, then assign a consistent identifier to each bucket or compartment visible in the inventory. For example, “Section A, bucket 1” and “Section B, bucket 1” avoid confusing two similarly marked units after removal or transport. Note whether a position appears occupied, spare, or unknown based on safe exterior observation and available records; do not open an enclosure to confirm. A spare bucket is an inventory item, not automatically a complete, usable starter or a match for another section. If drawings or prior schedules exist, label them as seller-provided records and note whether they identify the same section and bucket designations shown on the equipment.
Transcribe starter and breaker markings exactly
For each accessible bucket nameplate, transcribe the wording, numbers, units, and symbols exactly, preserving separate lines when practical. Distinguish a starter marking from a breaker marking: a motor starter and its protective device serve different functions, and one marking does not substitute for the other. Record any visible device designation without interpreting it as a load rating. If a label is incomplete, obscured, or inconsistent with an inventory sheet, write “partly unreadable” or quote only the legible text rather than filling in a likely value. Do not infer motor suitability, protection, or operating capacity from a starter description, breaker label, or the assembly’s 600 A designation.
Separate frame, trip, and device information
When a breaker label gives a frame rating and a separate trip marking, record both fields independently; do not collapse them into a single ampere figure. The frame identifies a breaker size or family characteristic, while the trip marking concerns the trip unit or trip setting as labeled. The exact meaning depends on the device and its documentation, so a number on the frame is not proof of the trip rating. Likewise, a bucket’s device marking is not the assembly rating. If a label has multiple numbers, include their printed captions and units. Avoid calculating a presumed setting or claiming coordination, suitability, or compatibility from a transcription alone.
Capture evidence from authorized safe positions
Useful documentation can include clear photographs of safely accessible exterior nameplates, section labels, bucket fronts, and visible condition, taken only from an authorized safe position. Never approach, touch, open, test, operate, disconnect, rack out, remove, or move energized equipment to obtain information or images. Electrical work and any access requiring electrical intervention must be performed by qualified, authorized personnel under site rules. Pair photographs with a written transcription so small characters can be checked without relying on image interpretation. Add the source of each record—such as a current exterior label, seller inventory, or drawing—and note discrepancies. No seller testing or equipment preparation is required for an initial review.
Submit the inventory for an individual assessment
Provide the section map, exact assembly and device markings, spare-bucket count, known condition, and any available records when requesting an assessment. Include the equipment’s voltage markings if safely available; the buyer considers equipment across all voltage classes, but voltage alone does not establish compatibility or acceptance. Offers are assessed item by item, with no assumed load, value, or outcome. The buyer makes cash offers and pays upfront for accepted purchases; buyer-paid freight can include crane, rigging, disconnects, loading, and hauling as appropriate to the agreed scope. Sellers do not need to test equipment or hire crews. The seller must own the equipment or have authority to sell it.