Identify the section by its place in the lineup
Start with the section’s physical position and designation, not an assumed function. Record any lineup drawing reference, section number, or label visible on an exterior nameplate from an authorized, safe position. Note whether the section is at an end, between other sections, or identified as the main section in site records; do not infer its role from appearance alone. A designation in a drawing may differ from a label in the field, so preserve both and note the source. If records are unavailable, describe the visible arrangement and mark the role as unconfirmed. This helps a buyer assess the section in context without overstating what it is.
Describe the assembled section separately from its breakers
A main section is not interchangeable with the breaker installed in it. Document the section or assembly identification separately from each visible breaker’s nameplate information, where safely accessible. If records identify a breaker by frame or trip rating, retain those as distinct fields rather than treating either as the assembly rating. Include the stated nominal voltage and other ratings only as printed or documented; do not derive them from a neighboring section. If a breaker is absent, removed, or listed separately in inventory, say so explicitly. This distinction matters when reviewing a partial lineup: a section may be offered with its installed components, without them, or alongside separately inventoried breakers.
Set a clear boundary for what is included
Draw an inclusion boundary around the offered asset. Specify whether the offer includes one main section alone, a continuous lineup, adjoining sections, separately stored breakers, or identified accessories and documentation. For example, if the main section remains connected to two adjacent sections, distinguish the proposed sale boundary from the physical lineup boundary; do not imply the neighboring sections are included merely because they appear in the same photograph. Note loose parts only when their identity and ownership are known. Identify items that are excluded or whose status is uncertain. The seller must own the equipment or have authority to sell it, so resolve ownership and inclusion questions before presenting the inventory for individual review.
Record known condition without testing
Summarize condition from existing records and observations already made from an authorized safe position. Useful details include whether the section is documented as complete, whether a breaker is recorded as missing, and whether records note damage, prior service, or an unknown history. Separate observed exterior conditions from statements copied from maintenance or decommissioning records, and identify uncertainty plainly. Do not energize, open, touch, test, disconnect, or move equipment to improve a listing or obtain photographs. No seller testing or preparation is required. Electrical work belongs to qualified, authorized personnel following site rules. Safe photographs may show exterior nameplates or the lineup from authorized safe positions, without approaching equipment to capture them.
Plan removal around the full lineup and site constraints
Handling a main section depends on its actual configuration, the proposed sale boundary, and site access—not simply the section’s label. Share available information about dimensions, weight, access route, overhead or doorway constraints, and whether the lineup is connected to adjoining sections, using records where possible. Do not estimate by appearance or arrange removal independently. If accepted after individual assessment, the buyer covers disconnects, crane and rigging, loading, freight, and hauling; qualified authorized personnel must perform electrical work under site rules. Explain any known access limits, lifting restrictions, or scheduling constraints so removal can be considered realistically. Do not promise that a particular method or outcome will apply.
Submit a useful inventory for individual review
Present the section designation, lineup context, assembly and breaker details, stated ratings, inclusion boundary, known condition, and available records together. A simple schedule can label each field as confirmed, record-sourced, observed externally, or unknown; that is more useful than filling gaps with assumptions. Include safely accessible exterior photographs only, and match image labels to inventory identifiers. We buy used, surplus, and decommissioned electrical equipment, including equipment from decommissioned data centers and shut-down power plants, across all voltage classes. We offer cash and pay upfront; assets and offers are assessed individually, with no guaranteed acceptance, price, or timetable. Clear section-level information lets the review focus on the actual assembly and accompanying lineup details.