In Lawrenceville, Georgia, a facility may have boxed motor starters in storage while a motor control center (MCC) lineup remains installed. Those are different sale items and are easier to assess when inventoried separately. This independent buyer considers used, surplus, and decommissioned electrical equipment across all voltage classes, including equipment from decommissioned data centers and shut-down power plants. Cash offers and upfront payment are available for purchases the buyer and seller agree to; each assessment is individual, with no guaranteed offer or schedule.

Separate loose starters from the lineup

Start the inventory on paper by listing boxed or otherwise loose starters apart from MCC sections that remain assembled or installed. For each item, note the quantity, any exterior manufacturer or catalog markings already visible, and whether the lineup is complete, partial, or of uncertain configuration. Do not infer that loose devices belong to a particular section simply because they are stored nearby. This separation helps the buyer evaluate distinct assets without asking the seller to unpack equipment, fabricate a count, or prepare components for inspection.

Describe what is known—and what is not

Existing records can clarify an MCC assessment: asset registers, purchase documents, drawings, prior maintenance files, and exterior nameplate information may establish identity or history. Report recorded values with their labels intact; do not merge nominal system voltage, assembly voltage, continuous-current rating, device frame, trip rating, or interrupting rating into one assumed specification. If records conflict or a detail is absent, mark it unknown rather than estimating. No new measurements or seller testing are required to request a purchase assessment, and an undocumented rating should not be presented as verified.

Photographs without entering an electrical hazard

When site rules permit, photographs can show safely accessible exterior surfaces and exterior labels or nameplates from an authorized safe position. Keep cabinet doors closed; do not photograph interiors, even if a section appears inactive. Never approach, touch, open, operate, test, disconnect, remove, or move equipment that is energized or could still be energized. If a photo cannot be taken from a permitted safe location, skip it and rely on existing records. All electrical work, if required for an agreed handover, belongs to qualified, authorized personnel working under the facility’s procedures.

Assess the MCC as an assembly, not a pile of devices

For installed or assembled sections, useful context includes the lineup’s apparent extent, whether sections are connected, and whether documentation identifies associated units. These observations should come from records or safe exterior viewing—not seller disassembly. The buyer may assess loose starters separately from an MCC lineup, and may determine that some items are outside the scope of a particular offer. A visual resemblance or shared brand name alone does not establish electrical compatibility, completeness, or suitability. Acceptance and value depend on the specific items and information reviewed, not on an assumed match between stored devices and the assembly.

Agree on scope, price, and payment before handover

Offers are made individually after reviewing the proposed assets and available information; neither a particular price nor a response or pickup date is guaranteed. If both parties agree to a purchase, the buyer makes a cash offer and pays upfront for that agreed purchase. Confirm in writing which loose starters and which MCC sections are included, along with any known exclusions and site-access conditions. An assessment is not a commitment to accept every listed item. Keep unrelated work, including building demolition and hazardous-material remediation, outside the equipment purchase unless separately arranged by the responsible parties.

Plan removal responsibilities without assigning seller labor

For an agreed purchase, the buyer covers necessary crane and rigging arrangements, disconnect work, loading, freight, and hauling as applicable to the agreed scope. The seller is not expected to hire or pay a removal crew. Coordinate access, scheduling, escort requirements, and site-specific restrictions before handover, but do not move or prepare electrical equipment yourself. Any disconnect or other electrical task must be handled only by qualified personnel authorized for the site and acting under its safety controls. Responsibility for removal applies to the agreed equipment; it does not mean the buyer undertakes general facility clearance.

Make the handover record match the actual items

Before collection, reconcile the written item list against the agreed purchase scope using records and observations made from safe, authorized positions. Note which boxed starters are included and identify the MCC sections by available exterior markings or existing asset references. Flag a discrepancy rather than asking staff to open a cabinet or shift equipment to resolve it. Site access and pickup timing must be coordinated, and remain subject to the parties’ agreement and site rules. A clear scope protects both sides while leaving all hazardous electrical handling to authorized professionals.

LET’S MAKE A DEAL

Ready to sell?
Let’s talk.

We buy electrical switchgear from decommissioned data centers and shut-down power plants, as well as other surplus equipment. Tell us what you have for a cash offer; payment is upfront, no seller testing is required, and we buy all voltage classes.

We handle all rigging and logistics: crane, rigging, disconnects, loading, freight and hauling are on us. Qualified personnel handle electrical disconnects. The seller does nothing but get paid.

Text Nameplate Photos

Photograph equipment only if safe. Do not open or touch energized equipment or disturb a live installation.